Criteria

Text:
Topic:
Content:
Display:

Results

Viewing 1 to 30 of 953
CURRENT
2017-08-09
Standard
AS20708/15B
No Scope Available
2017-08-03
WIP Standard
AS20708/7B
No Scope Available
2017-08-03
WIP Standard
AMS5643/H1025B
This specification covers a corrosion-resistant steel product in the solution and precipitation heat treated (H1025) condition.
2017-08-03
WIP Standard
AS20708/16B
No Scope Available
2017-08-03
WIP Standard
AS20708/17B
No Scope Available
2017-08-03
WIP Standard
AS20708/22B
No Scope Available
2017-08-03
WIP Standard
AS20708/39C
This specification covers the detail requirements for control transformer synchro, type 19CTB4b, 90 volt, 400 cycle.
2017-08-03
WIP Standard
AS20708/25B
This specification covers the detail requirements for control transformer synchro, type 16CTB4b, 90 volt, 400 cycle.
2017-08-03
WIP Standard
AS20708/31B
No Scope Available
2017-08-01
WIP Standard
J3117/2
Develop an SAE specification for "1000BASE-T1 Un-shielded and Shielded Single Twisted Pair Ethernet Cable" for 1Gbps high speed data application.
CURRENT
2017-07-24
Standard
ARP6216
This SAE Aerospace Recommended Practice (ARP) identifies the minimum requirements for the testing of insulated electrical wiring for on-aircraft, aeronautical and aerospace applications. The testing requirements defined herein, ensure that a wire fault can be found safely when using a high potential voltage tester (hipot). This test is intended to aid in finding a breach in the wire insulation, and not for the identification of the resistance of the insulation. The test method defined herein is limited to equipment which ia able to control and limit the DC output to 1500 VDC maximum. This type of wire dielectric tester is typically designed to trip on current leakage and not necessarily on arc detection. This test method is solely designed to identify gross/large wire insulation damage or degradation.
2017-07-18
WIP Standard
ARP6505
This AIR intends to better document and tabulate electrical load dynamics that influence power source capacity, power quality and stabiltiy.
CURRENT
2017-07-07
Standard
AS7974/5A
SCOPE IS UNAVAILABLE.
CURRENT
2017-07-07
Standard
AS85848/2A
SCOPE IS UNAVAILABLE.
CURRENT
2017-07-06
Standard
AS85848A
This specification establishes the requirements for various types of identification sleeving that will shrink to a predetermined size upon the application of heat after it has been marked. Continuous operating temperature ratings range from -55° to 175°C (-67° to 347°F). (See 6.1).
2017-06-28
WIP Standard
AS50881G
This specification covers all aspects in electrical wire interconnection systems (EWIS) from the selection through installation of wiring and wiring devices and optical cabling and termination devices used in aerospace vehicles. Aerospace vehicles include manned and unmanned airplanes, helicopters, lighter-than-air vehicles, missiles and external pods.
CURRENT
2017-06-20
Standard
AS85848/1A
SCOPE IS UNAVAILABLE.
2017-06-05
WIP Standard
AIR6808
This SAE Aerospace Information Report (AIR) is limited to the requirements of AS50881 and examines these requirements providing rationale behind them. SAE AS50881 is only applicable to the aircraft electrical wiring and interconnect system (EWIS). Pods and other devices that can be attached to an aircraft that are considered as aircraft equipment design. The AS50881 scope does not include attached devices, but does include the interface between the pod and aircraft wiring. Paragraph 3.3.5 addresses components such as antennas and other similar equipment that was once supplied as GFAE.
CURRENT
2017-05-26
Standard
J3117_201705
This document covers un-shielded balanced single twisted pair data cable intended for use in surface vehicle cables for 100 Mbps Ethernet applications. The tests in this document are intended to qualify cables for normal operation in an automotive environment while maintaining the necessary electrical properties for reliable data transmission.
CURRENT
2017-05-25
Standard
AS20708/131B
Scope is unavailable.
2017-05-22
WIP Standard
AIR6540
The scope of this report is to capture the fundamental principles of selecting a wire size for an aerospace application using the method prescribed in SAE AS50881 standard. Also, provided in this report are additional calculations to ensure the wire selection will adequately perform in a particular design function including meeting environment constraints. Some of the calculations in this report have been simplified to demonstrate the process for validating the wire size selections for a particular design application. More precise calculations should be investigated and evaluated to ensure proper assessment of each individual calculation in this report.
CURRENT
2017-05-22
Standard
AS5259/8
AS5259/8 IS DESIGNED TO FUNCTION AS A REMOTE ELECTRICAL PUMP VERSION OF THE AS5259/4-01 OR THE AS5259/5-01 BASIC TOOLS MANUAL PUMP VERSIONS. CRIMPING IS LIMITED TO WIRE SIZES 8 THROUGH 2 FOR INSULATED TERMINALS AND 8 THROUGH 00 FOR UN-INSULATED TERMINALS AND CONTACTS (SEE TABLE 1).
CURRENT
2017-05-22
Standard
AS20708/139B
SCOPE IS UNAVAILABLE.
CURRENT
2017-05-22
Standard
AS20708/500B
Scope is unavailable.
CURRENT
2017-05-18
Standard
AS20708/94C
This specification covers the detail requirements for 115 volt, 60 and 400 Hz, size 23 synchros (see 6.1).
2017-04-24
WIP Standard
AMS6457E

This specification covers a low alloy steel in the form of welding wire. Type 2 – Copper Coated wire was removed from this document (see 8.5).

CURRENT
2017-04-21
Standard
AIR6162
This document provides an orientation to fusion splicing technology for optical fibers and fiber optic cable. It is intended for managers, designers, installers, and repair and maintenance personnel who need to understand the process of fusion splicing. This technology is widely used in telecommunications and industrial applications, and is finding acceptance in aerospace applications.
CURRENT
2017-04-18
Standard
AS20708/67B
No Scope Available
CURRENT
2017-04-18
Standard
AS20708/74B
No Scope Available
Viewing 1 to 30 of 953